Photobiological safety report
WebThis report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma (point) is used as the decimal separator. WebCharles River performs in vitro photosafety evaluations, primarily the OECD 432/ICH S10-compliant in vitro 3T3 neutral red uptake phototoxicity testing. Along with the 3T3 assay, …
Photobiological safety report
Did you know?
WebTest Report No. 7191184238-EEC18/01-CMF dated 27 Apr 2024 Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the Gen-eral Terms and Conditions of Business of TÜV SÜD PSB Pte Ltd. In addition, this report is governed by the terms set out within this report. LA-2007-0380-A LA-2007-0381-F WebIssued: 2016-11-22 Page 6 of 21 Report No.: 4787397309 TRF No. IEC62471A General product information: Only photobiological hazards resulting from electric ally powered incoherent broadband sources of optical ra-diation have been addressed. The product covered by this report is a component LED Light Engine designated as Model HelioLux. This
WebSection 3.1 summarises UV-C safety requirements identified in the photobiological safety standard IEC 62471 [3]. It also alters the lower wavelength boundary from 200 nm to 180 nm to extend safety considerations to common 185 nm sources as outlined in the scope of this document. Section 3.2 WebThis report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the …
WebThis test report provides a photobiological assessment of the specified product under the guidance of the double-logo standard CIE/IEC 62471: Photobiological safety of lamps and … WebPhotobiological safety & Irradiance High Tech Campus 48, 5656 AE Eindhoven 24-Oct-2014 Photobiological safety evaluation report according to IEC 62471 200 200 Lamp Current n/a ( ± 5.8 %) 1.200 pass LUXEON TX L1T2-6570 PHILIPS Lumileds Lighting Company BV Hazards at viewing distance Sample 0002 RiskGroup Exempt Exempt RiskGroup 2 Exempt …
WebPhotobiological safety evaluation report according to IEC 62471 200-3000 26-Jan-2015 Horizontal. Report nr (6) 16 : JM10534A Date of report : Testfacility 14 : VarOptr Operator 10 : J.Marinus Responsible 11 : H.J.v.Aalderen E-mail: [email protected] Software Version : 1.6.1.0
WebGives guidance for evaluating the photobiological safety of lamps and lamp systems including luminaires. Specifically it specifies the exposure limits, reference measurement … oops building blocksWebThe test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing labo-ratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. oops businessWebANSI/IESNA RP-27 – Recommended Practice for Photobiological Safety for Lamps; CAN/CSA-C22.2 No. 62471:12 Photobiological safety of lamps … oops bread orlandoWebAug 31, 2024 · REPORT DATE; PTR-06: LUXEON 2835 Architectural and Colors: L128-xxxxxx350000x1 L128-xxxx003500000 for white L128-xxx1003500000 for colors (non … oops boba tea \\u0026 coffeeWebStrengthen Your Competitive Edge with LED Biological Effects Assessment. Photobiological testing allows manufacturers to evaluate the safety of lamps and lamp systems, including … iowa clinic bone densityWebno photobiological safety hazard issue. Sources are classified into the following four groups according to hazard, based on the emission limit as well as permissible exposure time before hazard exceeded: Exempt No Photobiological hazard Group 1 (Low-Risk) No Photobiological hazard under normal behavioral limitations Group 2 (Moderate-Risk) oops busto arsiziooops c#